Underwater Scanner Project
Sunday, December 1, 2013
Saturday, November 16, 2013
FEA Analysis
We were able to run the FEA analysis on our model so now we know what we need to change to make the model more suited to the pressure. This analysis is run at 50psi pressure from all sides.
Friday, November 1, 2013
Friday, October 18, 2013
Calculations of bending of light
I calculated (theta')1 maximum value in Lexan to Air. It helped me to calculate the max value of angle from which light is going to enter Lexan from water medium. I worked backwards when I got the theta' 1 and 2 values 39.2 and 86.92 respectively.
As theta 2 = theta' 1. Use theta 2=39.2 degrees to calculate theta 1(angle between water and lexan medium). We get theta 1 value as 46.85 degrees and it is the max value at which light will enter.
As theta 2 = theta' 1. Use theta 2=39.2 degrees to calculate theta 1(angle between water and lexan medium). We get theta 1 value as 46.85 degrees and it is the max value at which light will enter.
Scan lens Optics
Scan Lens
Sample images of scanner performance
I tried to take the scanner lens apart but I couldn't. I can take the whole case out but not just the lenses because it is a tight fit. The lens case has two lenses in it with different magnification and focal length. This is an estimation because when I touched the surface one is more bulged out than the other lens. I can't find it's focal length until I take them out and test them. I am going to try another way to find out the specifications of the lenses. They are made for specific scanners. The lenses Nathaniel gave me have same focal length and will not fit in that case as they are big to fit inside. But if we have to put extra lens to adjust the focal length we can always build a new case for it.
Good news:
I have got some values of refractive index and how light will bend for different materials and will do the calculations right away if I get the focal length of these length. I also figured out that if we make the box vacuum or leave the air inside it won't affect the properties of bending of light as vacuum and Air has almost same refractive index which is 1.
Refractive indices:
Air at STP - 1.000277
Air at 0 °C and 1 atm - 1.000293
Vacuum - 1
Water - 1.33
Lexan (poly-carbonate) - (1.584–1.586)
So, it will not affect much as I will count refractive index value till 3 significant digits.
I just need an idea to take the lens out of that case. I did research on it but couldn't find any video or article on it.
Sample images of scanner performance
I tried to take the scanner lens apart but I couldn't. I can take the whole case out but not just the lenses because it is a tight fit. The lens case has two lenses in it with different magnification and focal length. This is an estimation because when I touched the surface one is more bulged out than the other lens. I can't find it's focal length until I take them out and test them. I am going to try another way to find out the specifications of the lenses. They are made for specific scanners. The lenses Nathaniel gave me have same focal length and will not fit in that case as they are big to fit inside. But if we have to put extra lens to adjust the focal length we can always build a new case for it.
Good news:
I have got some values of refractive index and how light will bend for different materials and will do the calculations right away if I get the focal length of these length. I also figured out that if we make the box vacuum or leave the air inside it won't affect the properties of bending of light as vacuum and Air has almost same refractive index which is 1.
Refractive indices:
Air at STP - 1.000277
Air at 0 °C and 1 atm - 1.000293
Vacuum - 1
Water - 1.33
Lexan (poly-carbonate) - (1.584–1.586)
So, it will not affect much as I will count refractive index value till 3 significant digits.
I just need an idea to take the lens out of that case. I did research on it but couldn't find any video or article on it.
Subscribe to: